Electro Warmflo Electric Furnaces Techs and Specs
|
Electro Warmflo Electric Furnaces Specifications
|
Model
|
kW
|
Btu/h
|
Motor
|
Amps
|
Volts
|
Breakers
|
|
HE-A-10-21
|
10
|
31,000
|
1/2 HP
|
42
|
240
|
60
|
|
HE-A-15-21
|
15
|
51,000
|
1/2 HP
|
63
|
240
|
60,30
|
|
HE-A-20-21
|
20
|
68,000
|
1/2 HP
|
83
|
240
|
60,60
|
|
HE-H-10-21
|
10
|
31,000
|
1/2 HP
|
42
|
240
|
60
|
|
HE-H-15-21
|
15
|
51,000
|
1/2 HP
|
63
|
240
|
60,30
|
|
HE-H-20-21
|
20
|
68,000
|
1/2 HP
|
83
|
240
|
60,60
|
|
HE-E-10-21
|
10
|
31,000
|
1/2 HP
|
42
|
240
|
60
|
|
HE-E-15-21
|
15
|
51,000
|
1/2 HP
|
63
|
240
|
60,30
|
|
HE-E-20-21
|
20
|
68,000
|
1/2 HP
|
83
|
240
|
60,60
|
- 21"W x 32"H x 21"D
- Weight = 100lbs
- 1/2 HP ECM motor
- 700-1500 CFM
|
Electro WarmFlo Electric Furnace Shown with Options
Top Cabinet - Electro Warmflow Electric Furnace
Middle - Optional Heat Pump A-Coil - HE-ICC-21
This cabinet goes between the filter cabinet (left) and the WarmFlo Air Handler itself.
This allows coupling the Electro-Mate Air Handler with the contractor’s selected split
heat pump. To utilize WarmFlo temperature sensing and the proper operation of the WarmFlo
unit, the heat pump coil must be at the blower inlet.
In this arrangement the WarmFlo technology performance and comfort will “temper” the air source
heat pump output thus allowing the heat pump to operate down to at least 0° F and increasing the
overall system efficiency.
Air heat pump comfort is always guaranteed with WarmFlo. In addition the ECM variable speed
blower is also controlled by WarmFlo temperature sensing and its internal program.
Bottom - Optional Air Filter - HE-IF-21 (Recommended)
Designed for return air entering the bottom of the WarmFlo Air Handler blower cabinet (ideal).
Since the filter is within this cabinet, return air duct is connected directly to a provided
19”W x 16”H opening. Furnished with one screw-on filler plate, either side.
Internal “rails” for 4” standard pleated filter, 20” x 20”. Since all manufacturers’ 4” pleated
filter modules are not the same dimensions, there is a certain amount of field adjustment.
|
|